DA180 series basic AC servo drive Function codes
-152-
Delay after power-on
initialization
This parameter specifies the delay time of servo enabling after power-on initialization is completed.
6.5.4 Frequency-division output and second-encoder settings
Frequency-division
numerator of
external grating ruler
This parameter specifies the frequency-division numerator of the external grating ruler.
Frequency-division
denominator of
external grating ruler
This parameter specifies the frequency-division denominator of the external grating ruler. It
corresponds to the grating ruler pulses needed for each motor rotation.
Reverse external
grating ruler count
This parameter specifies whether to reverse the count from the external grating ruler.
Use the count from the external grating ruler directly.
Reverse the count from the external grating ruler and then
use the reversed count.