DA180 series basic AC servo drive Function codes
-118-
Switching delay in
torque control
In torque control, if P2.31 is set to 3, the first gain is switched back from the second gain. This
parameter specifies the time from the triggering to the actual switching.
Switching level in
torque control
In torque control, if P2.31 is set to 3, the trigger of gain switching must be set. The unit varies with
the switching mode and associated settings.
Note: The level must be equal to the lag at least.
Switching lag in
torque control
In torque control, if P2.31 is set to 3, the trigger of gain switching must be set to determine the lag.
The unit varies with the switching mode and associated settings.
Note: If the level is set to be less than the lag, the setting is changed to the level being equal to the
lag during the actual use.
6.3.3 Special motor control
This parameter specifies whether the disturbance observer is valid.