DA180 series basic AC servo drive Function codes
-157-
P4.93*
Read fault records
Setting range
Default
Unit
Applicable
mode
01
0
-
P
S
T
This parameter specifies whether to enable the function of reading fault records. If the function is
enabled, the fault records specified by P4.95 are read and displayed.
Setting
Meaning
[0]
Disable
1
Enable
P4.93*
Data size
16bit
Data format
DEC
Modbus address
1986, 1987
CANopen address
0x245D, 0x00
P4.94*
Clear fault records
Setting range
Default
Unit
Applicable
mode
01
0
-
P
S
T
This parameter specifies whether to enable the function of clearing fault records. If the function is
enabled, all the fault records are cleared.
Setting
Meaning
[0]
Disable
1
Enable
P4.94*
Data size
16bit
Data format
DEC
Modbus address
1988, 1989
CANopen address
0x245E, 0x00
P4.95*
Fault record group
no.
Setting range
Default
Unit
Applicable
mode
09
0
-
P
S
T
This parameter specifies the group number of fault records that are read.
The value 0 indicates the fault records in group 1 are read and the faults have occurred most
recently. The value 9 indicates the fault records in group 10 are read and the faults have occurred
earliest.
P4.95*
Data size
16bit
Data format
DEC
Modbus address
1990, 1991
CANopen address
0x245F, 0x00
P4.96*
Reserved
Setting
range
Default
Unit
Applicable
mode
-
-
-
P
S
T
This parameter cannot be modified.
P4.96*
Data size
16bit
Data format
DEC
Modbus address
1992, 1993
CANopen address
0x2460, 0x00