Loading...
DA180 series basic AC servo drive Appendix
-274-
Function
code
Parameter
Unit
Setting range
Default
Applicable
mode
P0.16
Parameter modification
lock
-
01
0
PST
P0.17
Mode for writing to
EEPROM
-
01
0
PST
P0.18*
Factory password
-
065535
0
PST
P0.19
Main circuit power input
type
-
01
0
PST
P0.20
1
Position command source
-
04
0
P
P0.22
1
Pulses per motor
resolution
reference unit
0(2
31
-1)
10000
P
P0.23
1
Pulse input mode
-
02
0
P
P0.24
1
Reverse pulse input
direction
-
01
0
P
P0.25
Numerator of electronic
gear ratio 1
-
0(2
31
-1)
0
P
P0.26
2
Denominator of electronic
gear ratio
-
1(2
31
-1)
10000
P
P0.27
Numerator of electronic
gear ratio 2
-
0(2
31
-1)
0
P
P0.28
Numerator of electronic
gear ratio 3
-
0(2
31
-1)
0
P
P0.29
Numerator of electronic
gear ratio 4
-
0(2
31
-1)
0
P
P0.33
2
Position command smooth
filter time
ms
0.01000.0
0.0
P
P0.34
2
Position command FIR
filter time
ms
0.01000.0
0.0
P
P0.35
Software limit in CCW
position control
reference unit
-(2
31
-1)(2
31
-1)
0
P
P0.36
Software limit in CW
position control
reference unit
-(2
31
-1)(2
31
-1)
0
P
P0.37
Position command mode
-
01
0
P
P0.40
Speed command source
-
05
1
S
P0.41
Speed command direction
setting
-
01
0
S
P0.42
Gain of AI 1
[P3.26 unit]/V
102000
100
PST