DA180 series basic AC servo drive Control modes
-37-
4.4.4.1 Digital input functions
Signal
Symbol
Function
Applicable
mode
Disabling forward drive
POT
0x01
P
S
T
Disabling reverse drive
NOT
0x02
P
S
T
Signal of disabling the drive to the forward or reverse direction. The detailed action is associated
with the setting of P3.40 [Disable travel limit switch].
If P3.40 is set to 0:
When the input of forward drive disabling is valid, the motor stops at the current position
and accepts the reverse command input only.
When the input of reverse drive disabling is valid, the motor stops at the current position
and accepts the forward command input only.
If P3.40 is set to 1, this function is invalid.
If P3.40 is set to 2 when the input of forward or reverse direction drive disabling is valid, the drive
alarms.
Signal
Symbol
Function
Applicable
mode
Enabling servo
SON
0x03
P
S
T
Signal of controlling whether to enable servo.
If it is valid, the drive powers on the motor. If it is invalid, the drive powers off the motor.
Signal
Symbol
Function
Applicable
mode
Clearing alarms
CLA
0x04
P
S
T
Signal of controlling whether to clear an alarm after the drive reports the alarm.
It may not be used to clear some alarms. For details, see section 10.4 "Fault codes".
Signal
Symbol
Function
Applicable
mode
Switching control modes
MCH
0x05
P
S
T
If P0.03 [Control mode] is set to 3, 4, or 5, the signal specifies control mode switching.
If the control mode is set to 0, 1, 2, 6, or 7, it is invalid.
Signal
Symbol
Function
Applicable
mode
Switching gains
PLC
0x06
P
S
T
Signal of controlling the switching between the first gain and second gain.