DA180 series basic AC servo drive Control modes
-41-
PtP2.53[Position of
segment 126]
PtP2.55[Position of
segment 127]
Signal of reporting an external fault alarm.
If this digital input is valid, the drive reports the alarm Er10-3 and stops.
Signal of controlling the switching between the first inertia ratio and second inertia ratio.
If this digital input is valid, the internal software uses P1.02. If it is invalid, the internal software
uses P1.01.
Signal of controlling emergency stop.
If P3.41 [Disable emergency stop] is set to 0 and this digital input is valid, the drive stops and
report the alarm Er10-4.
Input signal of the Home switch.
When the drive executes the homing action in some homing mode, , the drive completes the
homing action if this digital input is valid. For details, see the description for P5.10 [Homing
mode].