DA180 series basic AC servo drive Operating and running
-71-
MODESET
SET MODE
5.2.5.4 Program jogging
After the run parameters P5.00P5.05 are set, you can press MODE to switch to the auxiliary function
mode. Then you can press UP/DOWN to enter the menu and press SET to enter the
program jogging screen, displaying . Then you can press SHIFT to switch between
and to enable and disable program jogging. On the screen,
you can press UP or DOWN to start program jogging. The use of the UP or DOWN key is associated
with P5.00. If the motor running direction is counterclockwise, the UP key must be used for the
starting. If the motor running direction is clockwise, the Down key must be used for the starting. After
the starting, the current rotation speed of the motor is displayed.
SET
UP DOWN
MODE
MODE
MODE
SHIFTSHIFT
SHIFT
5.2.5.5 Inertia identifying
You can press MODE to switch to the auxiliary function mode. You can press UP/DOWN to enter the
menu and press SET to enter the inertia identifying menu, which displays .
Then you can press SET to enable inertia identifying. After inertia identifying is complete, the result
data such as is displayed about three seconds and then saved automatically. The
screen returns to the parameter setting menu automatically after displaying about two
seconds.