Goodrive300-19 series open loop vector inverter special for hosit Function parameters
-111-
Detailed instruction of parameters
Power
factor of the
motor
Display the current power factor of the motor.
Range: -1.00~1.00
Display the current running time of the inverter.
Range: 0~65535min
Current step
of the
multi-step
speed
Display the current stage of the multi-step speed
Range: 0~15
The percentage of the rated torque of the relative
motor, display ASR controller output
Range: -300.0%~300.0% (the rated current of the
motor)
Display the magnetic flux linkage of the motor.
Range: 0.0%~200.0%
Exciting
current
reference
Display the exciting current reference in the vector
control mode.
Range: -3000.0~3000.0A
Display the torque current reference in the vector
control mode.
Range: -3000.0~3000.0A
Display the value of inlet current in AC side.
Range: 0.0~5000.0A
Display the output torque, positive in electromotion
state and negative in power generation.
Range : -3000.0Nm~3000.0Nm
Count value
of motor
overload
0~100 (100 reports OL1 fault)
Current step
of
hierarchical
Display the current step of hierarchical multi-step
speed
Range: 0~6