Goodrive300-19 series open loop vector inverter special for hosit Function parameters
-111-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P17.25
Power
factor of the
motor
Display the current power factor of the motor.
Range: -1.00~1.00
0.0
P17.26
Current
running time
Display the current running time of the inverter.
Range: 0~65535min
0m
P17.27
Current step
of the
multi-step
speed
Display the current stage of the multi-step speed
Range: 0~15
0
P17.28
ASR
controller
output
The percentage of the rated torque of the relative
motor, display ASR controller output
Range: -300.0%~300.0% (the rated current of the
motor)
0.0%
P17.32
Magnetic
flux linkage
Display the magnetic flux linkage of the motor.
Range: 0.0%~200.0%
0.0%
P17.33
Exciting
current
reference
Display the exciting current reference in the vector
control mode.
Range: -3000.0~3000.0A
0.0A
P17.34
Torque
current
reference
Display the torque current reference in the vector
control mode.
Range: -3000.0~3000.0A
0.0A
P17.35
AC current
Display the value of inlet current in AC side.
Range: 0.0~5000.0A
0.0A
P17.36
Output
torque
Display the output torque, positive in electromotion
state and negative in power generation.
Range : -3000.0Nm~3000.0Nm
0.0Nm
P17.37
Count value
of motor
overload
0~100 (100 reports OL1 fault)
0
P17.38
Current step
of
hierarchical
Display the current step of hierarchical multi-step
speed
Range: 0~6
0