SV-DA200 series AC servo drives                                                                         Faults and solutions 
‐92‐
P0.27 
Data size  32bit  Data format  DEC 
Modbus address  1054,1055 CANopen address  0x201B, 0x00
P0.28 
Data size  32bit  Data format  DEC 
Modbus address  1056,1057 CANopen address  0x201C, 0x00
P0.29 
Data size  32bit  Data format  DEC 
Modbus address  1058,1059 CANopen address  0x201D, 0x00
 
P0.33
2
 
Smooth filtering of 
position command 
Setting range  Default  Unit  Available mode
0.0~1000.0  0.0  ms  P   F
This  parameter  is  used  to  set  the  time  constant  of  the  low  pass  filter  of  the  corresponding 
position and reduce the mechanical shock when the input pulse commands frequency changes. 
It is shown as the figure below: 
P0.33
2
 
Data size  16bit  Data format  DEC 
Modbus address  1066,1067 CANopen address  0x2021, 0x00
 
P0.34
2
 
FIR filter of position 
command   
Setting range Default  Unit  Available mode 
0.0~1000.0  0.0  ms  P F
This parameter is used to set the time constant of the FIR filter of the corresponding position and 
reduce the mechanical shock when the input pulse commands frequency changes. It is shown as 
the figure below: 
 
Note: If the parameter is modified during the operation, it will be valid after stopping. 
P0.34
2
 
Data size  16bit  Data format  DEC 
Modbus address  1068,1069 CANopen address  0x2022, 0x00