SV-DA200 series AC servo drives Faults and solutions
‐121‐
0x000~0x133 0x01A - P S T F
P3.06
1
Input configuration of digital 7 Setting range Default Unit Available mode
0x000~0x133 0x001 - P S T F
P3.07
1
Input configuration of digital 8 Setting range Default Unit Available mode
0x000~0x133 0x002 - P S T F
P3.08
1
Input configuration of digital 9 Setting range Default Unit Available mode
0x000~0x133 0x007 - P S T F
P3.09
1
Input configuration of digital 10 Setting range Default Unit Available mode
0x000~0x133 0x008 - P S T F
These parameters are used to set the input function of digital value 2~10, and they are hex
numbers.
The setting method is the same as P3.00.
Note: The default value is the function selection corresponds to position mode.
P3.01
1
Data size 16bit Data format HEX
Modbus address 1602, 1603 CANopen address 0x2301, 0x00
P3.02
1
Data size 16bit Data format HEX
Modbus address 1604, 1605 CANopen address 0x2302, 0x00
P3.03
1
Data size 16bit Data format HEX
Modbus address 1606, 1607 CANopen address 0x2303, 0x00
P3.04
1
Data size 16bit Data format HEX
Modbus address 1608, 1609 CANopen address 0x2304, 0x00
P3.05
1
Data size 16bit Data format HEX
Modbus address 1610, 1611 CANopen address 0x2305, 0x00
P3.06
1
Data size 16bit Data format HEX
Modbus address 1612, 1613 CANopen address 0x2306, 0x00
P3.07
1
Data size 16bit Data format HEX
Modbus address 1614, 1615 CANopen address 0x2307, 0x00
P3.08
1
Data size 16bit Data format HEX
Modbus address 1616, 1617 CANopen address 0x2308, 0x00
P3.09
1
Data size 16bit Data format HEX
Modbus address 1618, 1619 CANopen address 0x2309, 0x00
P3.10
1
Output configuration of
digital 1
Setting range Default Unit Available mode
0x000~0x11F 0x001 - P S T F
This parameter is used to select the configuration of the digital value 1 output function. It is a hex
number.
0x ——: means valid mode: 0: optical coupler conduction valid; 1: optical coupler
non-conduction valid
0x—﹡﹡: ﹡﹡means the selected function, the detailed information is as below: