38 Chapter 4: Exp/11A Expansion Unit TempScan / MultiScan User's Manual
Exp/11A Slave Address Settings Exp/11A Channel Assignments
Microswitches
1 and 2
Slave
Address
Slave Unit Logical
Unit
Card
Slot
TempScan/1100
Master Unit
MultiScan/1200
Master Unit
(N/A)
(N/A) (Master Unit)
(1)
(1) (Inputs 1 – 32) (Inputs 1 – 24)
1 Inputs 33 – 64 Inputs 25 – 48
2 Inputs 65 – 96 Inputs 49 – 72
3 Inputs 97 – 128 Inputs 73 – 96
4 Inputs 129 – 160 Inputs 97 – 120
5 Inputs 161 – 192 Inputs 121 – 144
6 Inputs 193 – 224 Inputs 145 – 168
7 Inputs 225 – 256 Inputs 169 – 192
8 Inputs 257 – 288 Inputs 193 – 216
9 Inputs 289 – 320 Inputs 217 – 240
0 0
0Slave 1
2
10 Inputs 321 – 352 Inputs 241 – 264
1 Inputs 353 – 384 Inputs 265 – 288
2 Inputs 385 – 416 Inputs 289 – 312
3 Inputs 417 – 448 Inputs 313 – 336
4 Inputs 449 – 480 Inputs 337 – 360
5 Inputs 481 – 512 Inputs 361 – 384
6 Inputs 513 – 544 Inputs 385 – 408
7 Inputs 545 – 576 Inputs 409 – 432
8 Inputs 577 – 608 Inputs 433 – 456
9 Inputs 609 – 640 Inputs 457 – 480
0 1
1Slave 2
3
10 Inputs 641 – 672 Inputs 481 – 504
1 Inputs 673 – 704 Inputs 505 – 528
2 Inputs 705 – 736 Inputs 529 – 552
3 Inputs 737 – 768 Inputs 553 – 576
4 Inputs 769 – 800 Inputs 577 – 600
5 Inputs 801 – 832 Inputs 601 – 624
6 Inputs 833 – 864 Inputs 625 – 648
7 Inputs 865 – 896 Inputs 649 – 672
8 Inputs 897 – 928 Inputs 673 – 696
9 Inputs 929 – 960 Inputs 697 – 720
1 0
2Slave 3
4
10 Inputs 961 – 992 Inputs 721 – 744
(1 1)
(3) (Invalid)
(N/A)
(N/A) (N/A) (N/A)