Further technical
details
ipNTP - DCF77 Desktop DIN-Rail Unit
Interfaces
1 x antenna DCF77
1 x 10BaseT – RJ45 (can be operated in networks with 10/100 MBit/s)
Diagnosis-LEDs
Power, System,
DCF77 Takt, Time Sync,
Ethernet Send/Receive/Link
Supply voltage + 8 - 14 V DC – Input Jack
+ 8 - 14 oder 18 – 36 (24V) V DC
1)
Input Jack and 3,5mm connector
Accuracy
DCF77 receipt: ± 8 msec.
Free ru operties: ± 10 ppm at constant tenning pr mperature (+10°C to +50°C)
Emergency clock: ± 50 ppm
Housing Plastic housing Plastic housing
Dimensions W/H/D Approx. 110/30/75 mm Approx. 45/108/73 mm
Operating/Storage temperature 5° C to 55° C / -10° C to 70° C
Relative humidity 5 % to 90 % non-condensing
Standards CE
ipNTP & DCF77 antenna approx. 2,50 m,
Configuration software,
Driver for Windows (NT, 2000, XP),
Documentation (German or English)
Scope of delivery
Power supply
In: 230 V AC Out: + 9 V DC
Without power supply
(Optionally)
Order number 0202018 0202018-H24
1)
Further voltages on request
2)
Delivery only at countries with 230 V
AC 50Hz
ipNTP - GPS Tischgerät Hutschienengerät
Interfaces
1x GPS receiver
1 x 10BaseT - RJ45 (can be operated in networks with 10/100 Mbit/s)
Diagnosis-LEDs
Power, Antenna,
GPS Send/Receive,
Ethernet Send/Receive/Link
Supply voltage + 8 - 14 V DC – Input Jack
+ 8 - 14 or 18 – 36 (24V) V DC 1)
Input Jack and
3,5 mm connector
Accuracy
GPS impulse: ± 300 nsec.
Fre ± 2 ppm after o e-running properties: VCO regulation at constant temperature (+10°C t
+50°C)
emergency clock: ± 50 ppm
Housing Plastic housing Plastic housing
Dimensions W/H/D Approx. 110/30/75 mm Approx. 45/108/73 mm
Operating/Storage
temperature
5° C to 55° C / -10° C to 70° C
Relative humidity 5% to 90 % non-condensing
Standards CE
Configuration software,
Driver for Windows (NT, 2000, XP),
Documentation (German or English) Scope of delivery
Power supply 2)
In: 230 V AC Out: + 9 V DC
Without power supply
(optionally)
Order number 0202019 0202019-H24
1)
Further voltages on request
2)
Delivery only at countries with 230 V AC 50Hz
Änderungen vorbehalten Stand 09.09.05
ipcas GmbH ipEther232 V11.01 Seite 108 von 150