Power Supply Function
The reset behavior of a component in its environment is si-
mulated and tested. Test boundary conditions (e.g., assem-
bly, terminal, system) must be described in detail. During
operation, an arbitrary sequence of repeated switching-on/
off procedures occurs; this must not lead to an undefined be-
havior of the component. The reset behavior is represented
by a voltage variance and a time variance. Two different test
sequences are required to simulate different switch-off
times. A component must always undergo both sequences.
E-10 Start impulses
During a cold start (motor start), the energy storage battery
voltage decreases for a short, then increases again. The
warm start is not considered, because the operating range is
maintained.
Normal Standard experimental pulse
Severe Enhanced experimental pulse
E-15 Operation in the range without function restriction
The operating behavior at the range limits is checked.
E-16 Operation in the upper range with function limitation
The operating behavior with change and at the range limits
is checked.
E-18 Overvoltage range
The test is to show the load cut-off during storage charging
and check the changes of the operating behavior into the
overvoltage range.
E-01
The waveform is as follows:
Copyright © Itech Electronic Co., Ltd.