Technical Specification
Parameter IT6006B-800-25
Working
Temperature
050
Dimension ( mm) 483mm(W)*801.61mm(D)*151.3mm(H)
Weight( net)
20KG
*1. The instrument needs to be customized under other AC input voltage
ranges. For models equipped with an emergency stop module (including AC
contactor), the AC input voltage range can only be: 342V528V.
7.1.11 IT6012B-800-50
Source Mode
Parameter IT6012B-800-50
Rated value ( 0 -50 )
Output Voltage
0800V
Output Current
-5050A
Output Power
-1212kW
Output Resistance
01Ω
Line Regulation Voltage
≤0.01%FS
±(of Output+Offset)
Current ≤0.05%FS
Load Regulation Voltage
≤0.02%S
±(of Output+Offset)
Current ≤0.05%FS
Setup Resolution
Voltage
0.01V
Current 0.01A
Power 0.001kW
Resistance 0.001Ω
Read Back Resolution
Voltage
0.01V
Current 0.01A
Power 0.001kW
Resistance 0.001Ω
Setup Accuracy (within 12
months, 25 ±5) ±(
ofOutput+Offset)
Voltage
≤0.02% + 0.02%FS
Current ≤0.1% + 0.1%FS
Power ≤0.5% + 0.5%FS
Resistance ≤1% + 1%FS