Technical Specification
Parameter IT6012B-500-80
Readback stability-
8h (%of Output
+Offset)
Voltage
≤0.02% + 0.02%FS
Current ≤0.1% + 0.1%FS
Input impedance
quiescent current
<7mA at Vmax
Efficiency
~92%
Remote Sense
Compensation
Voltage
≤5V
Command Re-
sponse Time
2Ms
Storage
Temperature
-10℃~70℃
Protective Function
OVP, OCP, OPP, UVP, OTP, Vsense protect
Standard Interface
Standard: USB, CAN, LAN, VCP,
optional: GPIB, RS232
Isolation (input to
ground)
1000V
Working
Temperature
0~50℃
Dimension ( mm) 483mm(W)*801.61mm(D)*151.3mm(H)
Weight( net)
30KG
*1. The instrument needs to be customized under other AC input voltage
ranges. For models equipped with an emergency stop module (including AC
contactor), the AC input voltage range can only be: 342V~528V.
7.1.9 IT6018B-500-120
Source Mode
Parameter IT6018B-500-120
Rated value
Output Voltage
0~500V
( 0 ℃-50 ℃) Output Current
-120~120A
Output Power
-18~18kW
Output Resistance
0~1Ω
Line Regulation Voltage
≤0.01%FS
±(%of Output+Offset)
Current ≤0.05%FS
Copyright © Itech Electronic Co., Ltd.
261