Basic Operation
Category
Parameter Initial Value
Current setting under CC
mode: Is
0A
Power setting under CW mode:
Ps
0W
Resistance setting under CR
mode: Rs
Rated maximum resist-
ance value of the
instrument
Voltage setting under CVCC
mode: Vs
Rated voltage of the
instrument
Current setting under CVCC
mode: Is
0A
Voltage setting under CVCR
mode: Vs
Rated voltage of the
instrument
Resistance setting under
CVCR mode: Rs
Rated maximum resist-
ance value of the
instrument
Current setting under CRCC
mode: Is
0A
Resistance setting under
CRCC mode: Rs
Rated maximum resist-
ance value of the
instrument
Voltage setting under AUTO
mode: Vs
Rated voltage of the
instrument
Current setting under AUTO
mode: Is
0A
Power setting under AUTO
mode: Ps
0W
Resistance setting under AU-
TO mode: Rs
Rated maximum resist-
ance value of the
instrument
On/Off state Off
Config
menu(Load
mode)
Operation mode CC
I-Rise Slope 0.1A/ms
I-Fall Slope 0.1A/ms
Von mode Latch
Copyright © Itech Electronic Co., Ltd.
178