Technical Specification
Parameter IT6018B-500-120
Input power
018kW
Input resistance
0.0017500Ω
Min. operating
voltage
2.4V at 120A
Setup Resolution
Voltage
0.01V
Current 0.01A
Power 0.001kW
Resistance 0.001Ω
Read Back
Resolution
Voltage
0.01V
Current 0.01A
Power 0.001kW
Resistance 0.001Ω
Setup Accuracy
(within 12 months,
25 ±5) ±(
ofOutput+Offset)
Voltage
≤0.02% + 0.02%FS
Current ≤0.1% + 0.1%FS
Power ≤0.5% + 0.5%FS
Resistance ≤1% + 1%FS
Read Back Accu-
racy (within 12
months, 25 ±5)
±(of Output
+Offset)
Voltage
≤0.02% + 0.02%FS
Current ≤0.1% + 0.1%FS
Power ≤0.5% + 0.5%FS
Resistance ≤1% + 1%FS
Setup Temperature
Coefficient ±(of
Output/+Offset)
Voltage
≤50PPM/
Current ≤200PPM/
Read Back Temper-
ature Coefficient
±(of Output/
+Offset)
Voltage
≤50PPM/
Current ≤200PPM/
Dynamic
Rising slope
120A/ms
Falling slope
120A/ms
Dynamic Frequency
500Hz
Min. rise time ≤1ms
Output parameter
Output voltage
range (Three-phase
four-wire)
198V264V (Derating 50%)
342V528V
Output frequency
range
47Hz63Hz
Copyright © Itech Electronic Co., Ltd.
264

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6000B Series and is the answer not in the manual?

ITech IT6000B Series Specifications

General IconGeneral
BrandITech
ModelIT6000B Series
CategoryPower Supply
LanguageEnglish

Related product manuals