Basic Operation
Copyright © Itech Electronic Co., Ltd. 29
IT6402/IT6412/IT6412S
7. If the OVP protection function is on, the icon is displayed on the
display screen.
Over Voltage Protection(OVP)
Software over-voltage protection: when the over-voltage protection is
enabled, the voltage at the power output terminal is limited to the value set
by the over voltage protection. If the over-voltage protection is triggered,
the output will immediately be switched off and the LCD display will show
.
Hardware over-voltage protection: when the over-voltage protection is
disabled, the maximum input voltage of the power supply is limited to about
120% of the present voltage range. If the hardware over-voltage protection
is triggered, the output will be immediately switched off and the LCD
display will show . To avoid damage to the internal elements of the
product, please avoid that the external voltage loaded on the output
terminal is over 120% of the rated voltage.
Clear OVP: When the power supply occurs OVP, firstly cut off the DUT.
Select “Menu > System > Sys Conf” on the interface to enter the System
Menu interface. Select System Protection Clear by the Up/Down Key and