List Function
Copyright © Itech Electronic Co., Ltd. 65
Chapter7 List Function
This chapter describes the features and use of the List function of the IT6400
series power supply in details.
7.1 Basic Concepts
The User can edit the test procedures composed of several steps through the
List function. There are 20 Lists (List 0 to List 19) under the List function for
selection, which can be controlled through the Select parameters on the
interface. Values are as follows:
⚫ Y: this List is selected and executable.
⚫ N: this List is neither selected nor executable.
The User can flexibly select the List to form different sequence output. A
maximum of 30 steps (Point 0 to Point 29) can be configured in each List. The
User can edit the voltage, current, resistance and step time. Relationship
between List and Sequence is shown below.
Introduction of List interface
⚫ IT6411/IT6431/IT6432/IT6433/IT6411S/IT6432S