List Function
Copyright © Itech Electronic Co., Ltd. 68
External import of List
The IT6400 series power supply is provided with external import of List
documents. The User can import the local-edited List documents to the power
supply. This function simplifies the List document edit and facilitates user
operation. Detailed operation steps are as below:
1. Create a new Excel document on local PC and name it ListCHx.
2. Open the Excel document and save it as in “other formats” in “(*.csv)”.
3. Open the ListCHx.csv document and edit the List. Set every step of the List
and corresponding parameters.
4. Insert the USB (containing ListCHx.csv document) to the USB interface on
the front panel of power supply.
5. On the List Function interface, press the right [Channel 1/2] soft key to
select configuring channel, for example CH1. (Only IT6402/IT6412/
IT6412S contain this step.)
6. By the , move the cursor to the List setting place and press the
Numeric key or Knob to set the List number value.
7. Press the [External Import] soft key and the power supply will
automatically identify the .csv document in the USB and import it.
IT6411/IT6431/IT6432/IT6433/IT6411S/IT6432S

Table of Contents

Other manuals for ITech IT6400 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6400 Series and is the answer not in the manual?

ITech IT6400 Series Specifications

General IconGeneral
BrandITech
ModelIT6400 Series
CategoryPower Supply
LanguageEnglish

Related product manuals