Input Settings
Copyright © ITECH Electronic Co., Ltd. 22
Chapter5 Input Settings
These commands control the input of the electronic load. The INPut, CURRent,
RESistance and VOLTage commands program the actual input current,
resistance, and voltage.
[SOURce:]INPut <bool>
This command is used to set the input status.
Command Syntax
[SOURce:]INPut <bool>
Parameters
0 | 1 | OFF | ON
*RST Value
OFF
Examples
INP 1
Query Syntax
INPut[:STATe]?
Returned Parameters
0 | 1
[SOURce:]INPut?
This command is used to query the input status.
Command Syntax
[SOURce:]INPut?
*RST Value
OFF
Examples
INP?
[SOURce:]INPut:SHORt <bool>
This command is used to set the status of short circuit function.
Command Syntax
[SOURce:]INPut:SHORt <bool>