Input Settings
Copyright © ITECH Electronic Co., Ltd. 39
*RST Value
MIN
Examples
DYN:LOW 1
Query Syntax
[SOURce:]DYNamic:LOW[:LEVel]?
Returned Parameters
<NR2>
[SOURce:]DYNamic:LOW[:LEVel]?
This command is used to query the low-level load current in dynamic mode.
Command Syntax
[SOURce:]DYNamic:LOW[:LEVel]?
Parameters
None
Unit
A
*RST Value
0
[SOURce:]DYNamic:LOW:DWELl <NRf+>
This command is used to set the duration of low-level load current in dynamic
mode.
Command Syntax
[SOURce:]DYNamic:LOW:DWELl <NRf+>
Parameters
MIN~MAX|MINimum|MAXimum
Unit
S
*RST Value
MIN
Examples
DYN:LOW:DWEL 1