OCP Testing Commands
Copyright © ITECH Electronic Co., Ltd. 52
OCP:VTRig?
This command is used to query the OCP trigger level.
Command Syntax
OCP:VTRig?
Returned Parameters
MIN~MAX
Unit
V
OCP:RESult[:OCP]?
This command is used to query the current value of OCP.
Command Syntax
OCP:RESult[:OCP]?
Returned Parameters
<NRf+>
Unit
A
Examples
OCP:RES?
Returned Parameters
4.68
OCP:RESult:PMAX?
This command is used to query the PMAX value.
Command Syntax
OCP:RESult:PMAX?
Returned Parameters
<NR2>,<NR2>,<NR2>
Unit
W V A
Examples
OCP:RES:PMAX?