IEEE488 Commands 
  Copyright © ITECH Electronic Co., Ltd.  71 
Default value
 
see *PSC 
*STB? 
This query reads the Status Byte register, which contains the status summary 
bits and the Output Queue MAV bit. Reading the Status Byte register does not 
clear it. The input summary bits are cleared when the appropriate event 
registers are read (see chapter “Programming the Status Registers” for more 
information). A serial poll also returns the value of the Status Byte register, 
except that bit 6 returns Request for Service (RQS) instead of Master Status 
Summary (MSS). A serial poll clears RQS, but not MSS. When MSS is set, it 
indicates that the electronic load has one or more reasons for requesting 
service. 
Query Syntax 
*STB? 
Parameters 
None 
Returned Parameters 
<NR1> (register value) 
Related Commands 
*SRE     *ESR     *ESE 
*TST? 
This command causes the electronic load to do a self-test and report any error. 
The reference information for the return value is as follows: 
0: indicates no error 
1: indicates that the module failed to initialize. 
3: indicates that the module calibration data is lost. 
4 or 5: indicates EEPROM error 
Command Syntax 
TST? 
Parameters 
None 
Returned Parameters 
<NR1> 0 indicates the electronic load has passed selftest. 
Non-zero indicates an error code. 
*TRG 