EasyManua.ls Logo

ITech IT8500plus Series - [Source:]Current:slew:fall; [Source:]Current:protection[:Level] <Nrf

ITech IT8500plus Series
85 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Input Settings
Copyright © ITECH Electronic Co., Ltd. 28
Examples
CURR:SLEW FALL 3
Query Syntax
[SOURce:]CURRent:SLEW:FALL?
Returned Parameters
<NR2>
[SOURce:]CURRent:SLEW:FALL?
This command is used to query the slew rate of the current for negative going
transitions.
Command Syntax
[SOURce:]CURRent:SLEW:FALL?
Parameters
None
Unit
A/uS
*RST Value
MAXimum
[SOURce:]CURRent:PROTection[:LEVel] <NRf+>
This command sets the current protection level. If the input current exceeds the
current protection level for the time specified by CURR:PROT:DEL, the input is
turned off.
NOTE: Use CURR:PROT:DEL to prevent momentary current limit conditions
caused by programmed changes from tripping the overcurrent protection.
Command Syntax
[SOURce:]CURRent:PROTection[:LEVel] <NRf+>
Parameters
MIN ~ MAX | MINimum | MAXimum
Unit
A
*RST Value
MAXimum