EasyManua.ls Logo

ITech IT8500plus Series - [Source:]Dynamic:high:dwell; [Source:]Dynamic:low[:Level] <Nrf

ITech IT8500plus Series
85 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Input Settings
Copyright © ITECH Electronic Co., Ltd. 38
Parameters
MIN~MAX|MINimum|MAXimum
Unit
S
*RST Value
MIN
Examples
DYN:HIGH:DWELl 0.01
Query Syntax
[SOURce:]DYNamic:HIGH:DWELl?
Returned Parameters
<NR2>
[SOURce:]DYNamic:HIGH:DWELl?
This command is used to query the duration of high-level load current in
dynamic mode.
Command Syntax
[SOURce:]DYNamic:HIGH:DWELl?
Parameters
None
Unit
S
*RST Value
MIN
[SOURce:]DYNamic:LOW[:LEVel] <NRf+>
This command is used to set the low-level load current in dynamic mode.
Command Syntax
[SOURce:]DYNamic:LOW[:LEVel] <NRf+>
Parameters
MIN~MAX|MINimum|MAXimum
Unit
A

Table of Contents

Other manuals for ITech IT8500plus Series

Related product manuals