ITech IT8500plus Series - [Source:]Current[:Level][:Immediate][:Amplitude] <Nrf; [Source:]Current[:Level][:Immediate][:Amplitude]

ITech IT8500plus Series
85 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Input Settings
Copyright © ITECH Electronic Co., Ltd. 33
CURRent: Constant Current Mode
VOLTage: Constant Voltage Mode
POWer: Constant Power Mode
RESistance: Constant Resistance Mode
DYNamic: Dynamic Operation Mode
LED: LED Mode
IMPedance: Constant Impedance Mode
*RST Value
CURRent
Examples
MODE RES
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]
<NRf+>
This command is used to set the current setting in CC mode.
Command Syntax
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude] <NRf+>
Parameters
MIN~MAX|MINimum|MAXimum
Unit
A
*RST Value
MINimum
Examples
CURR 5
Query Syntax
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]?
Returned Parameters
<NR2>
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]?
This command is used to query the current setting in CC mode.
Command Syntax
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]?

Table of Contents