EasyManua.ls Logo

Jandy APUREM - Figure 12. Pipe Cutout; Figure 13. Pipe Cutout (Option 3 - Replace 2-Port Cell and Piping and Treat as New Installation)

Jandy APUREM
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 12. Pipe Cutout
Universal Unions and Nuts
For a 2" pipe, the cutout is 13⅞" with
the full unions.
For a 50 mm pipe, the cutout is 352 mm
with the full unions.
NOTE: Total length of the electrolytic
cell with the full unions is 16⅝".
Sensor Port Plug and Nut
Figure 13. Pipe Cutout (Option 3 - Replace 2-Port Cell and Piping and treat as New Installation)
Universal Unions and Nuts
For a 2" pipe, the cutout is 13⅞" with
the full unions.
For a 50 mm pipe, the cutout is 352 mm
with the full unions.
NOTE: Total length of the electrolytic
cell with the full unions is 16⅝".
Sensor Port
Straight or Reducing Coupler
Total length of the 2-port electrolytic cell
with full unions is
15"
Cut out cell and tee section of piping. Allow enough
room to glue in straight couplers and pipe to
accommodate 3-port cell requirements (see below).
Total length of the PVC
Tee is 4¼”
Straight or Reducing Coupler
Page 22
ENGLISH
Page 22
ENGLISH
Jandy
®
AquaPure
®
/PureLink™ Power Center and Cell Kit
|
Installation and Operation Manual

Table of Contents