Figure 12. Pipe Cutout
Universal Unions and Nuts
For a 2" pipe, the cutout is 13⅞" with
the full unions.
For a 50 mm pipe, the cutout is 352 mm
with the full unions.
NOTE: Total length of the electrolytic
cell with the full unions is 16⅝".
Sensor Port Plug and Nut
Figure 13. Pipe Cutout (Option 3 - Replace 2-Port Cell and Piping and treat as New Installation)
Universal Unions and Nuts
For a 2" pipe, the cutout is 13⅞" with
the full unions.
For a 50 mm pipe, the cutout is 352 mm
with the full unions.
NOTE: Total length of the electrolytic
cell with the full unions is 16⅝".
Sensor Port
Straight or Reducing Coupler
Total length of the 2-port electrolytic cell
with full unions is
15"
Cut out cell and tee section of piping. Allow enough
room to glue in straight couplers and pipe to
accommodate 3-port cell requirements (see below).
Total length of the PVC
Tee is 4¼”
Straight or Reducing Coupler
Page 22
ENGLISH
Page 22
ENGLISH
Jandy
®
AquaPure
®
/PureLink™ Power Center and Cell Kit
|
Installation and Operation Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jandy APUREM and is the answer not in the manual?

Jandy APUREM Specifications

General IconGeneral
BrandJandy
ModelAPUREM
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals