7.2 Service Codes
Code Number Possible Cause Corrective Action
120 Low current in forward direction to Cell. 1. Clean cell if necessary (see Section 6.3).
2. Check DC Cord.
121 Low current in reverse direction to Cell. 1. Clean cell if necessary (see Section 6.3).
2. Check DC Cord.
123 Extremely Low current to Cell.
1. Clean or replace cell if necessary (see Section 6.3).
2. Check DC Cord.
124 Higher than normal Current to Cell. Contact a pool professional.
125 Cell needs to be cleaned. Clean cell if necessary (see Section 6.3).
126 Low current in forward direction and VAC input
voltage below 100/200 VAC.
Contact a pool professional.
127 Low current in reverse direction and VAC input
voltage below 100/200 VAC.
Contact a pool professional.
144 Low Salinity (below 2.0 gpl). Add salt to pool to achieve 3.0 gpl (see Section 4.7).
145 High Salinity (above 4.0 gpl). BackwashlterifaDElterisinstalled.Partially
drain pool and dilute with fresh water until salinity
returns to 3.0 to 3.5 gpl.
170 Possible Front board service condition or unit not
correctly wired to 120 VAC.
Contact a pool professional.
171 Possible Backboard service condition. Contact a pool professional.
172 FlowSensorserviceconditionorowsensoris
unplugged.
Contact a pool professional.
173 Low VAC input voltage and on board power supply is
not regulated or unit not correctly wired.
Unit wired to improper AC voltage. Contact a pool
professional.
174 Pool Temperature is too high for operation of
AquaPure.
Flow/Salinity Sensor indicates water temperature
at sensor above 108ºF (42°C). Reduce water
temperature.
175 Flow Sensor air lock condition or very low salinity. Verifyproperow/temp/salinitysensorinstallation
(see Section 3, Figure 11). Check salinity with Myron
“L” meter calibrated for NaCl or test strips. Add salt
as necessary (see Sections 4.5 through 4.7).
7.3 Level 2 Service Codes
If you encounter a Level 2 Service Code, contact your local pool professional for service.
Code Number Possible Cause Corrective Action
180 Heated sensor element not heating.
(Generates 172 code)
Contact a pool professional.
181 Flow sensor temperature sensor failure.
(Generates172code-owsensorservice))
Contact a pool professional.
182 Salinity Sensor sees less than 0.2 gpl of salt, no salt
in pool or sensor air locked.
(Generates175code–owsensorairlock)
Contact a pool professional.
183-186 Flow salinity sensor temperature probe error codes.
(Theywillallgenerate172codeswhichindicateow
sensor service is required)
Contact a pool professional.
Page 43
ENGLISH
Page 43
ENGLISH
Jandy
®
AquaPure
®
/PureLink™ Power Center and Cell Kit
|
Installation and Operation Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jandy APUREM and is the answer not in the manual?

Jandy APUREM Specifications

General IconGeneral
BrandJandy
ModelAPUREM
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals