EasyManuals Logo

Jandy APUREM User Manual

Jandy APUREM
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #42 background imageLoading...
Page #42 background image
Problem Possible Cause Corrective Action
“Service” Indicator On. Low salt level in pool water. Test salinity. Add salt as described in
Section 4.7.
Cell requires cleaning. Refer to Maintenance Procedure for acid
wash cleaning. See Section 6.3, Step 2.
Cell not working properly after cleaning Contact a pool professional.
DC power cord not properly connected to
the cell.
Check connection. Check for dirt or
corrosion around DC cord contacts at cell.
Check Cell studs for same.
Flow/Temp/Salinity Sensor not plugged in. Plugow/temp/salinitysensorintoconnector
on power center printed circuit board. (Cycle
Power).
Water temperature too low Winterize your pool. See Section 6.5,
Winterizing.
All the above have been checked and
indicator light is still on.
Contact a pool professional.
Problem Possible Cause
Corrective Action
Salt Level Too Low. Not enough salt added on start up. Add salt to pool, 3.0 gpl to 3.5 gpl. See
Section 4.7.
Heavy Rainfall. Add salt to pool, 3.0 gpl to 3.5 gpl. See
Section 4.7.
Leak in pool. Repair pool.
Dirtyow/temp/salinitysensorcontacts
or faulty sensor.
Removeandcleanow/temp/salinitysensor
contacts.Checkow/temp/salinitysensor
cable for damage. See Section 6.4. Verify
salinity with Myron “L” meter calibrated for
NaCl, titration test units, or other salt meters.
Please be aware that salt test strips have a
large variance in readings (400 - 800 ppm).
Problem Possible Cause
Corrective Action
Chlorine Odour. Presence of excess chloramines (combined
chlorine).
Manually shock the pool following the
directions in Section 5.4.1 Shocking.
Problem Possible Cause
Corrective Action
Cloudy Water, Slimy Walls of
Pool.
Combined algae and bacteria growth. Brush down the affected walls and follow the
directions in Section 5.4.1 Shocking.
Problem Possible Cause
Corrective Action
Eye and/or skin irritation. Improper water balance. Balance the water to recommended levels in
Section 4.5.
Problem Possible Cause
Corrective Action
Scale formation on pool
equipment.
NOTE: To clean the deposit
(scale) on the electrolytic cell
plates, see Section 6.3.
Incorrect pH causing metals to come out of
solution.
Adjusttotalalkalinityto80-120ppm.Then
adjustpHtowithintherange7.4-7.6.See
Section 4.5.
High total hardness. Dilute pool with fresh water. Consult your
pool professional regarding use of a
sequestering agent.
Page 42
ENGLISH
Page 42
ENGLISH
Jandy
®
AquaPure
®
/PureLink™ Power Center and Cell Kit
|
Installation and Operation Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jandy APUREM and is the answer not in the manual?

Jandy APUREM Specifications

General IconGeneral
BrandJandy
ModelAPUREM
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals