EasyManuals Logo

Jandy APUREM User Manual

Jandy APUREM
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #33 background imageLoading...
Page #33 background image
CELL REVERSING
The automatic cleaning cycle is in progress. The cleaning cycle is factory set and
cannot be adjusted. Cell Reversing does not interrupt the production of chlorine.
SALINITY
Salinity is displayed along with the gpl (grams per liter) indicator, when the
SALINITY button (C) is depressed. If a reading of HH appears, the salinity is above
4.5 to 6.5 gpl (depending on pool temperature) and is too high to measure correctly
(at normal temperatures). Maintain salinity between 3.0 and 3.5 gpl. See Section 4.
ADD SALT
The ADD SALT indicator comes on when the ow/temp/salinity sensor determines
that the salinity level of the pool water is too low. Maintain Salinity between 3.0
and 3.5 gpl.
SERVICE and
Service Code
The SERVICE indicator will turn on whenever the control system detects a problem
that requires attention. The SERVICE indicator is accompanied by a service code
displayed on the front panel, displayed as a 3 digit code. The service code(s) are
displayed twice per minute with an audible alarm.
NOTE See Section 7.2, Service Codes.ProblemscanrangefrominsufcientsalinitytotheDCcordnotconnected.
Audible Alarm
An audible alarm (beep) sounds once per hour, and only for the rst service code,
when a SERVICE condition is detected. The alarm can be cleared by pressing and
holding the SALINITY button (C) for 5 seconds. The audible alarm can be cleared
for 24 hours or until the power to the unit is turned off and back on whichever
comes rst. However, the audible alarm will return if a new problem is detected.
NOTE TheaudiblealarmcanbepermanentlydisabledbyremovingthejumperfromJ2onthecontrol/powercenter
Power Interface Board (PIB).
Audible Alarm
Volume Control
Audible alarm operation and volume control can be adjusted. To adjust volume
control, press and hold the TEMPERATURE button (D) for 15 seconds. The system
will beep once when pressed, once after 10 seconds and once after 15 seconds.
Release the key after the third beep. Press the SALINITY button (C) within 5
seconds to enter the temperature change screen.
NOTE The boost cycle is normally activated after 10 seconds, however, if the key is held
down until after the third beep at 15 seconds, the Boost mode will not be changed.
The system will display a ‘1’ followed by ‘F’ or ‘C’. Press the TEMPERATURE
button (D) to move to the second parameter screen. The screen will display a 0, and
the alarm volume will be fully reduced. The system will occasionally show a ‘2’ to
display the screen number. Press the arrow button B to increase the volume and the
arrow button A to reduce the volume. The volume increments from 0 to 100 in 20
steps. After each press of the arrow buttons, the alarm will activate to demonstrate
the current volume level. When the alarm volume has been adjusted to the desired
setting, press the SALINITY button (C) to conrm the new alarm volume setting.
The change will be stored in permanent memory. If you do not wish to keep the
change, wait 5 seconds, and the change screen will ‘time out’ and return to normal
operation without keeping any changes to the system. Any changes made to the
alarm volume will NOT be saved if this occurs.
Page 33
ENGLISH
Page 33
ENGLISH
Jandy
®
AquaPure
®
/PureLink™ Power Center and Cell Kit
|
Installation and Operation Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jandy APUREM and is the answer not in the manual?

Jandy APUREM Specifications

General IconGeneral
BrandJandy
ModelAPUREM
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals