NT–2000 REF Manual
Control Panel Functions
2-7
2. Control Panel Functions (
continued – 7/10
)
⑭ Message/Station Rejection Key
– 1/2
・ When a NAVTEX message text is currently being displayed, pressing this key
displays a summary list of the transmitter IDs and message types rejected
(deselected) via the
*
1
menu system on both the first and second receivers, as in
the example below.
Figure 2-9 List of Currently Rejected Stations and Message Types – Example
*
1
:
→ SYSTEM MENU → 4:MAKE SEL/REJ SETTING
Detailed instructions are given in paragraph 4.8.
*
2
* SECOND RECEIVER 1 = 490 kHz, SECOND RECEIVER 2 = 4209.5 kHz
・ The following message types cannot be rejected due to the relevant IMO
resolutions and IEC regulations related to navigational safety:.
- Type A: Navigational Warning
- Type B: Meteorological Warning
- Type D :
SAR (search and rescue) Information, Piracy or Armed Robbery Warning
- Type L: Additional Navigational Warning
・ To turn off the above lists, press either
.
Pressing
turns the lists off and displays the SYSTEM MENU.
(
continued on next page
)
REJECTED STATIONS:
REJECTED MESSAGES:
G I M
N O P Q R S T U W X Y
< FIRST RECEIVER >
REJECTED STATIONS:
REJECTED MESSAGES:
G I M
N O P Q R S T U W X Y
< SECOND RECEIVER *
2
1 >