INDOOR UNITS
3-36
TC-15001-rev.3
3.1.5 Ducted Slim
3.1.5.1 General Data
NOTES:
*1. Nominal capacity is based on combinations within the VRF system and the following:
Cooling Operation Conditions
Indoor Air Inlet Temperature: 80°F DB (26.7°C DB)
67°F WB (19.4°C WB)
Outdoor Air Inlet Temperature: 95°F DB (35.0°C DB)
Heating Operation Conditions
Indoor Air Inlet Temperature: 70°F DB (21.1°C DB)
Outdoor Air Inlet Temperature: 47°F DB (8.3°C DB)
43°F WB (6.1°C WB)
Piping Length: 24 ft. 7-3/16 in. (7.5m)
Piping Lift: 0 ft. (0m)
*2. The sound pressure level is based on the following.
4.9 ft. (1.5m) beneath the unit.
With Discharge Duct 6.6 ft. (2.0m) and Return Duct 3.3 ft. (1.0m)
7KHDERYHGDWDZDVPHDVXUHGLQDQDQHFKRLFFKDPEHUVRWKDWUHÀHFWHGVRXQGVKRXOGEHWDNHQLQWRFRQVLGHUDWLRQLQWKH¿HOG
*3. The data for external pressure *3) indicates “Standard Pressure Setting (High Pressure Setting - Low Pressure Setting)” values
ZKHQD¿OWHULVQRWXVHG7KHVRXQGSUHVVXUHOHYHOLVEDVHGRQWKH6WDQGDUG3UHVVXUH6HWWLQJ
Indoor Unit Type Ducted Slim
Model (H,Y)IDS006B21S (H,Y)IDS008B21S (H,Y)IDS012B21S (H,Y)IDS015B21S (H,Y)IDS018B21S
Indoor Unit Power Supply AC 1Phase, 208/230V, 60Hz
Nominal Cooling Capacity *1 Btu/h 15,000 18,000
N: (4.4) (5.3)
Nominal Heating Capacity *1 Btu/h 17,000 20,000
N: (5.0) (5.9)
dB 36-35-33-32 40-38-36-34
Outer Dimensions
Height in.(mm) 7-9/16 (192) 7-9/16 (192) 7-9/16 (192) 7-9/16 (192) 7-9/16 (192)
Width in.(mm) 35-3/4 (908) 35-3/4 (908) 35-3/4 (908) 46-3/8 (1178) 46-3/8 (1178)
Depth in.(mm) 17-19/32 (447) 17-19/32 (447) 17-19/32 (447) 17-19/32 (447) 17-19/32 (447)
1HW:HLJKW OEVNJ          
Refrigerant
Indoor Fan
Airflow Rate cfm 512-477-441-381 582-530-494-424
(Hi2-Hi-Me-Lo)
(
m
3
/min
)
(15-14-13-11) (17-15-14-12)
External Pressure *3
in.W.G
0.04 (0.12-0.00) 0.04 (0.12-0.00) 0.04 (0.12-0.00) 0.04 (0.20-0.00) 0.04 (0.20-0.00)
(Pa)
(10 (30-0)) (10 (30-0)) (10 (30-0)) (10 (50-0)) (10 (50-0))
Motor Nominal Output W 60 60
Connections
Refrigerant Piping
Liquid Line in.(mm) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 3/8 (9.52)
Gas Line in.(mm) 1/2 (12.70) 1/2 (12.70) 1/2 (12.70) 1/2 (12.70) 5/8 (15.88)
Condensate Drain VP25 VP25
OD in.(mm) 1-1/4 (32) 1-1/4 (32) 1-1/4 (32) 1-1/4 (32) 1-1/4 (32)
ID in.(mm) 31/32 (25) 31/32 (25) 31/32 (25) 31/32 (25) 31/32 (25)
6RXQG3UHVVXUH/HYHO
6,000 8,000 12,000
(1.8) (2.3) (3.5)
6,700 9,000 13,500
318-289-244-205 318-289-244-205 346-318-300-268
(2.0) (2.6) (4.0)
2YHUDOO$6FDOH
+L+L0H/R
32-30-29-27 32-30-29-27 34-33.5-33-32
R410A
Flare-Nut Connection (with Flare Nuts)
VP25 VP25 VP25
(9-8-7-6) (9-8-7-6) (10-9-9-8)
40 40 40

Table of Contents

Other manuals for Johnson Controls (H,Y,C)IDM012B21S

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Johnson Controls (H,Y,C)IDM012B21S and is the answer not in the manual?

Johnson Controls (H,Y,C)IDM012B21S Specifications

General IconGeneral
BrandJohnson Controls
Model(H, Y, C)IDM012B21S
CategoryAir Conditioner
LanguageEnglish

Related product manuals