Chapter6 PC (Server/Client) Setup
VDR/S-VDR Real Time Monitor / Installation Manual
48
Explains how to set up the Visual block.
Connection)
Set the connection type of Radar unit.
Shows the detail of connection type the following table so that select a type and set.
Connection Type
Connection
FGB1(VDR)
※Built in VDR
FGB2(Option)
※Radar IF(NWP-46)
Note
None
- -
None connection to Radar
Case1 Radar1
- Radar1(X-Band)
Assume connection of above unit.
Case2 Radar1 Radar3
・Radar1(X-Band)
・Radar3(ECDIS)
Assume connection of above unit.
Case3 Radar1
Radar3+Radar4 ・Radar1(X-Band)
・Radar3(ECDIS)
・Radar4(Other Image)
Assume connection of above unit.
Case4
Radar1+Radar2 - ・Radar1(X-Band)
・Radar2(S-Band)
Assume connection of above unit.
Case5
Radar1+Radar2
Radar3
・Radar1(X-Band)
・Radar2(S-Band)
・Radar3(ECDIS)
Assume connection of above unit.
Case6
Radar1+Radar2 Radar3+Radar4 ・Radar1(X-Band)
・Radar2(S-Band)
・Radar3(ECDIS)
・Radar4(Other Image)
Assume connection of above unit.
Connection