Chapter6 PC (Server/Client) Setup
VDR/S-VDR Real Time Monitor / Installation Manual
47
Table6.3 Setup Contents in the System Tab
No. Block Content Setup*1 Note
①
Sensor
Existing of A/D and Dry Contact is indicated. If the unit exists, “✓” is
displayed.
U The contents gotten
from the VDR configu-
ration.
Monitor
To monitor audio, input
“✓”.
②
Audio
Record
To record audio, input
“✓”.
N
Connect Select a connection type.
Record
To record the image, input
“✓”.
Model Input the model of equipment whose image is
captured
Maker Input the maker of equipment whose images is
captured.
③
Visual
Serial No. Input the Serial Number of equipment whose images
is captured.
N
To select the
Connection, refer to
next page for more
detail.
In case of FGB1, the
contents gotten from
the VDR configuration.
④
Terminal
If the Client PC of the VDR/S-VDR Real Time Monitor exists, input
“✓”.
Do not select the Broadcast. PCs in user LAN other than the VDR/S-VDR
Real Time Monitor may be influenced.
N
To distribute to Client
PC, it is necessary to
set Client PC IP
address in the Ethernet
tab.
For The usage of the selected folder is shown either for
playback-only or record & playback by the mode.
U
Folder Select a folder for playback and record. N
Ship’s Name
IMO No.
Ship's Name and IMO number registered in the VDR
configuration data are displayed.
U
⑤
Setup Folder
[Initialize] button The selected folder is initialized. N
⑥
PC Card Drive Drive Select a drive of CF card with the button. N
When there is not
record mode or
playback mode, the
inputs to the items are
prevented.
⑦
System Files [Default] button If the system files are broken, the files are repaired. U
Overwrite To continue to record by overwrite after passing the
record period, input
“✓”.
When there is not
“✓” and the record period is
passed, the record is stopped automatically.
N
Record Period Input the record period. N
HDD Free
Space Limit
It is a limitation value of the HDD free space to
prevent all space being used by the recording. The
value is fixed with 1GB, and can not change it.
U
⑧
Record
Time to Warning
after Record
Stop
It is a timer value for indicating the warning screen
when record is paused.
The time is fixed with one hour, and can not change it.
U
When there is no
record mode, the inputs
to the items are
prevented.
Source Data It is a source data for time correction.
⑨
Time
Correction
Adjustment It is an adjustment value for time correction.
The time is fixed with 500 milliseconds, and can not
change it.
U
*1: N: Necessary, U: Unnecessary