Chapter8 Trouble Shooting
VDR Real Time Monitor / Installation Manual
59
Chapter8 Trouble Shooting
Table8.1 In case of Server
No. Symptom Cause Action
Faulty wiring of a LAN cable Check the connections. 1 The real time indication is not
possible.
Initial setup for real time
output is not completed by
the Maintenance software
yet.
Set the Option PC setup by the
Maintenance software.
⇒Refer to Chapter 5.
2 The image indication is not
possible.
The Power of a captured
display is not turned on.
Turn on power of a captured
display.
Audio monitoring is not
validated.
Validate audio monitoring by
the Setup software.
⇒Refer to Table 6.5-2.
Audio volume of the VDR
Real Time Monitor is low.
Or mute is validated.
Adjust the Volume or invalidate
the Mute.
3 There are no audio outputs of
the real time.
Audio volume of the Windows
or is low.
Or mute is validated.
Adjust the Volume or invalidate
the Mute in the “Volume
Control” and “Wave”.
Faulty wiring of the external
HDD
Check the connections. 4 The record is not possible.
The power of the external
HDD power is not turned on.
Turn on the power of the
external HDD.
5 The audio recording is not
possible.
The audio recording is not
necessary.
Validate the record by the
Setup software.
⇒Refer to Table 6.5-2.
6 The image recording is not
possible
The image recording is not
necessary.
Validate the record by the
Setup software.
⇒Refer to Table 6.5-2.
7 Record data are less than a
record period.
The free space of the HDD is
not enough for the record
period.
Increase a free space by
deleting unnecessary data, or
exchange to a mass HDD
8
When a LAN cable of the VDR
Real Time Monitor is
disconnected, it is not possible
to playback.
The [Connect] button is
pressed and operation is in
the state of LAN connection.
In order to operate under
disconnecting the LAN, please
press the [Disconnect] button in
the Setup software.
⇒Refer to Table 6.5-3.