STEP 3 Set by the Setup software of Server PC
Install the VDR/S-VDR Real Time Monitor software in accordance with “9.4 Install Flow for
Server PC”, and set by the Setup software.
(1) System tab screen
Input “” when monitor or record in the Audio block is needed.
Input “” when connection or record in the FGB block is needed, and input the Radar
information.
Input “” to Terminal 1, 2 and 3 in Terminal block since there are 3 Client PCs.
Select the record folder when the VDR/S-VDR Real Time Monitor PC records.
Set record period in the Record block when recording.
Folder
FGB
Audio
Record
Terminal