141 Setting of Selection of accessory devices is performed. — S 40
accessory
devices
142 Setting of Setting of the simplified program is performed. — S 41
simplified
program
143 Brake start angle The reserve brake start angle after thread trimming 0 to 10 S 41
when the thread is specified. (°)
trimming stop at
the upper position
144 Setting of The alternate vertical output is automatically 0 to 30 U 41
stitches count canceled by the predetermined stitching count. (Stitches)
for canceling 0 : Disabled
alternate 1 to 30 stitches
vertical output
145 Alternate The delay time from turning on the alternate vertical 0 to 500 S 41
vertical switch to output start is specified (ms)
output delay 0 : Disabled
time 10 to 500 (ms)
146 Selection of The alternate vertical ON/OFF output is forcibly 0 to 2 U 41
alternate provided after thread trimming.
vertical output 0: Retention of output state
after thread 1 : OFF output
trimming 2 : ON output
147 Alternate The alternate vertical output at power on can be set 0 to 2 U 41
vertical initial to ON or OFF.
output 0 : Resumes the state when the power was turned
off the last time
1 : Output OFF
2 : Output ON
148 2-pitch output The alternate vertical ON/OFF output is forcibly 0 to 2 U 41
during reverse provided after thread trimming.
feed stitching 0 : Retention of output state
at sewing start 1 : OFF output
or end 2 : ON output
149 2-pitch inverted The 2-pitch inverted output in synchronism with the 0/1 U 41
output during alternate vertical output can be set to present or
alternate absent.
vertical output 0 : Function disabled
1 : Function enabled
150 2-pitch initial The 2-pitch output at power on can be set to ON or 0 to 2 U 41
output OFF.
0 : Resumes the state when the power was turned
off the last time
1 : Output OFF
2 : Output ON
151 Tie stitch Stitching temporarily stops at start, end, and each 0/1 U 42
adjustment corner of overlapping stitching.
function 0 : Function disabled
1 : Function enabled
152 Temporary stop No. 151 : Temporary stop time is specified when the 0 to 100 S 42
time for tie tie stitch adjustment function is active. 0 (ms)
stitch
adjustment
153 Temporary stop The brake angle for temporary stop is specified o to 180 S 42
brake angle for when the tie stitch adjustment function is active. (°)
tie stitch (0: angle of starting down position detection)
adjustment
No. Item Description Setting range Setting level