EasyManuals Logo

JUKI SC-922 Engineer's Manual

JUKI SC-922
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
– 28 –
3
5
1
0
141 Setting of Selection of accessory devices is performed. S 40
accessory
devices
142 Setting of Setting of the simplified program is performed. S 41
simplified
program
143 Brake start angle The reserve brake start angle after thread trimming 0 to 10 S 41
when the thread is specified. (°)
trimming stop at
the upper position
144 Setting of The alternate vertical output is automatically 0 to 30 U 41
stitches count canceled by the predetermined stitching count. (Stitches)
for canceling 0 : Disabled
alternate 1 to 30 stitches
vertical output
145 Alternate The delay time from turning on the alternate vertical 0 to 500 S 41
vertical switch to output start is specified (ms)
output delay 0 : Disabled
time 10 to 500 (ms)
146 Selection of The alternate vertical ON/OFF output is forcibly 0 to 2 U 41
alternate provided after thread trimming.
vertical output 0: Retention of output state
after thread 1 : OFF output
trimming 2 : ON output
147 Alternate The alternate vertical output at power on can be set 0 to 2 U 41
vertical initial to ON or OFF.
output 0 : Resumes the state when the power was turned
off the last time
1 : Output OFF
2 : Output ON
148 2-pitch output The alternate vertical ON/OFF output is forcibly 0 to 2 U 41
during reverse provided after thread trimming.
feed stitching 0 : Retention of output state
at sewing start 1 : OFF output
or end 2 : ON output
149 2-pitch inverted The 2-pitch inverted output in synchronism with the 0/1 U 41
output during alternate vertical output can be set to present or
alternate absent.
vertical output 0 : Function disabled
1 : Function enabled
150 2-pitch initial The 2-pitch output at power on can be set to ON or 0 to 2 U 41
output OFF.
0 : Resumes the state when the power was turned
off the last time
1 : Output OFF
2 : Output ON
151 Tie stitch Stitching temporarily stops at start, end, and each 0/1 U 42
adjustment corner of overlapping stitching.
function 0 : Function disabled
1 : Function enabled
152 Temporary stop No. 151 : Temporary stop time is specified when the 0 to 100 S 42
time for tie tie stitch adjustment function is active. 0 (ms)
stitch
adjustment
153 Temporary stop The brake angle for temporary stop is specified o to 180 S 42
brake angle for when the tie stitch adjustment function is active. (°)
tie stitch (0: angle of starting down position detection)
adjustment
No. Item Description Setting range Setting level
(Start level ; U : Users mode, S : Service mode)
2
4
1
o
r
P
3
4
1
0
4
4
1
0
5
4
1
0
1
6
4
1
0
7
4
1
0
8
4
1
0
9
4
1
0
0
5
1
0
1
5
1
0
2
5
1
0
Indication of
function setting
Ref.
page
Do not change the set values with asterisk () mark as they are functions for maintenance. If the standard set value set at the time
of delivery is changed, it is in danger of causing the machine to be broken or the performance to be deteriorated.
1
4
1
n
U
F

Table of Contents

Other manuals for JUKI SC-922

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the JUKI SC-922 and is the answer not in the manual?

JUKI SC-922 Specifications

General IconGeneral
BrandJUKI
ModelSC-922
CategorySewing Machine
LanguageEnglish

Related product manuals