Figure 46: LMR400 Cable Connecons
Juniper has tested this topology with the following LMR400 cables:
LMR400 (10 m segment) from TE Connecvity. For more informaon, see Figure 47 on page 91.
LMR400 (100 m segment) from TE Connecvity. For more informaon, see Figure 48 on page 92.
LMR400 (5 m segment) from TE Connecvity. For more informaon, see Figure 49 on page 92.
You must ensure that you install a surge protector to protect the GNSS receiver from lightning surges.
This topology uses TVA-03C surge protectors. For more informaon about the surge protectors, see
Coaxial lightning arrestor TVA-03.
Figure 47: LMR400 (10 m Segment) Cable Specicaons
91