Initializing the EX2500 Ethernet Switch 19
Chapter 2: Installing the EX2500 Ethernet Switch
The console port’s terminal-emulation requirements are as follows:
Default baud rate = 9,600 bps
Character size = 8 characters
Parity = none
Stop bits = 1
Data bits = 8
Flow control = none
The switch performs initial self tests, and displays the
Password: prompt:
Memory Test ................................
Production Mode
PPCBoot 0.0.0.10 (new flash)
Memory Test (0x00) .............................PASSED
...
Juniper Networks EX2500 Ethernet Switch
Jan 1 00:01:27 2009:
NOTICE-5:Interface Oper Status Indication - Port 7 State UP
Password:
At the Password: prompt, enter the switch password, and press Enter. The default
password is admin
Default Configuration
The switch software contains default configuration files that are loaded at the
factory. The default configuration is part of the software; it cannot be deleted or
changed. The default settings allow the switch to perform basic functions with
minimal effort by the system administrator.
Configuring an IP Interface
To manage the switch using Telnet, SNMP, or a Web browser, you must configure
an IP interface. Configure the following IP parameters:
IP address
Subnet mask
Gateway address