14. Power on the services gateway by pressing the Power button on the front panel of the SFB for three
to five seconds. Wait for the services gateway to start.
15. Verify that the SFB is functioning normally by checking the LEDs on its faceplate. The SFB STATUS
LED should light steadily green a few minutes after the services gateway is powered on. If the SFB
STATUS LED is red, remove and install the SFB again. If the SFB STATUS LED still lights steadily red,
the SFB is not functioning properly. Contact your customer support representative.
To check the status of the SFB:
user@host> show chassis environment fpc 0
CB 0 status:
State Online Master
Temperature 30 degrees C / 86 degrees F
Power 1
1.2 V 1202 mV
1.5 V 1511 mV
1.8 V 1798 mV
2.5 V 2481 mV
3.3 V 3306 mV
5.0 V 4956 mV
12.0 V 12084 mV
1.25 V 1250 mV
3.3 V SM3 3287 mV
5.0 V RE 5046 mV
12.0 V RE 11910 mV
Power 2
11.3 V bias PEM 11292 mV
11.3 V bias FPD 11156 mV
11.3 V bias POE 0 11253 mV
11.3 V bias POE 1 11272 mV
Bus Revision 42
FPGA Revision 1
RELATED DOCUMENTATION
Required Tools and Parts for Replacing Hardware Components on the SRX3600 Services Gateway | 200
Replacing a Routing Engine on the SRX3600 Services Gateway | 210
Replacing a CFM Card on the SRX3600 Services Gateway | 216
Replacing an AC Power Supply on the SRX3600 Services Gateway | 230
209