No.
Item Reference picture/drawing Procedure
2-18
8 <Tension arm sub-assembly position adjustment> 1)Without loading a tape, set the mechanism mode
to PLAY mode.
To switch the mode, rotate worm wheel 2 while the
motor bracket assembly is disengaged (see 2.2,
Mechanism Modes).
2)Rotate the tension arm slightly clockwise to elimi-
nate production of rattle with the band arm plate.
3)Ensure that the notch on the tension arm is located
within area A. (See Fig. 2-7-8(e).)
4)If the tension arm is not located in area A, loosen
screw B (black) lightly and fine-adjust the position
of the band arm plate assembly. Turn the screw
counterclockwise to move the tension arm extrem-
ity toward the right or clockwise to move it toward
the left.
5)After the adjustment, clamp the band holder by
tightening screw B (black) (with a securing torque
of 5.88 Nm, or 0.6 kgf-cm). Then adjust the ten-
sion arm position again.
Fig. 2-7-8(d)
Fig. 2-7-8(e)
Notch on tension arm
Notch on tension arm
Tension arm
Band arm plate
Turn the tension arm
in the clockwise direction.
Joint between the tension arm
and band arm plate
(must not rattle here.)
Counterclockwise
direction
Clockwise
direction
Band holder
No Good
No Good
Position alignment point
Screw
B (Black)
OK (Upper limit)
OK (Lower limit)
OK (Center)
A