Technical Manual Product Description
1904045376 - 05/2016Kaba access manager 92 30
3.4.5 Interfaces
Ethernet interface
• IEEE802.3 compatible 10BASE-T/100BASE-TX Auto sensing, Auto MDIX.
RS-485
B-COMM mode:
• 2-wire subpartyline for connecting readers/subterminals
• Transmission parameters: 19,200 baud, 7 data bits, even parity, 1 stop bit
• Protocol: BPA/9 subset
exos mode:
• 2-wire subpartyline for connecting readers
• Transmission parameters: 19,200 baud, 8 data bits, even parity, 1 stop bit
• Protocol: KCP
RS-232
• Serial interface for specific applications
• Transmission parameters can be set via the terminal software.
Wiegand
• 2 Wiegand interfaces for connection of external lasers
• 5 V DC or 12 V DC power supply for the reader
HF-RFID
• 2 registration units with or without PIN keypad (connections ant. A and ant. B)
• Coaxial cable, impedance 50 Ohm
• Encrypted data transmission
3.4.6 Reader
Depending on the reader configuration, the registration units allow reading and writ-
ing of MIFARE or LEGIC media.
MIFARE
• RFID standard: ISO 14443A
• Supported badge media:
– MIFARE DESFire
– MIFARE Classic
LEGIC
• RFID standard: ISO 14443A, ISO 15693, LEGIC RF
• Supported badge media:
– LEGIC advant
– LEGIC prime