Installation Technical Manual
64 04045376 - 05/2016 Kaba access manager 92 30
5.7.9 Standard assignment of inputs/outputs (B-Client AC30)
The following assignment for the inputs and outputs has been preset for the B-
Client AC30 terminal software [}5.7.10.3].
The assignment of the functions can be adjusted in the b_client_ac30.ini configura-
tion file. Details on the configuration can be found in the B-Client AC30 reference
manual.
5.7.9.1 Inputs
The following functions are assigned by default to the inputs by the terminal soft-
ware.
Input Connection Function
BI01 IN1 Door frame contact 1
BI02 IN2 Door-opener key 1
BI03 IN3 Door frame contact 2
BI04 IN4 Door-opener key 2
BI36 IN5 Vandal contact
5.7.9.2 Outputs
The following functions are assigned by default to the outputs by the terminal soft-
ware.
Output Connection Function
BO01 OUT1 Door opener relay Door 1
BO02 OUT2 Door opener relay Door 2
BO20 OUT3 General alarm