Technical Manual Start-up
7704045376 - 05/2016Kaba access manager 92 30
6.4.6 Host settings
Setting of the communication type and definition of the host computer.
Function call: Menu > SETTINGS > Network > Host Settings
Communication via Ethernet / UDP
This is the standard communication type
1. Set the “ETH/UDP” interface.
2. Enter the IP address of the computer communicating with the terminal software
in the “Host name or IP address” field. If a DNS has been configured, it is also pos-
sible to specify the host name in this field.
3. In the “Port” field, select the UDP port used for communication. It is specified in
hexadecimal format. Possible values are 7700 to 77EF.
Communication via Ethernet / XML
This communication type is a precondition for HTTP/HTTPS-based applications that
are used directly as communication software instead of B-COMM.
1. Set the "ETH/XML" interface.
2. Enter the IP address of the computer communicating with the terminal software
in the “Host name or IP address” field. If a DNS has been configured, it is also pos-
sible to specify the host name in this field.
3. In the “Port” field, select the UDP port used for communication. It is specified in
hexadecimal format. Possible values are 7700 to 77EF.
Automatic registration
This function allows the device to be operated almost automatically. The device re-
ports cyclically to the active B-COMMs in the network and is then registered [}6.2]
by them.
The function can be enabled or disabled by means of the "Host Registration" check
box.