44
N. TESTING THE OPERATION OF THE LOCK
N-1 Rotate inside lever and hold. Ensure that the latch is fully retracted and
flush with the latch faceplate. Release the inside lever; the latch should be
fully extended.
N-2 For E-Plex PowerStarâ„¢, you need to activate the outside lever 3 to 4 times
to power the lock prior
N-3 If your product is an E2xxx, enter the factory-set combination:
1,2,3,4,5,6,7,8. If your lock is a PowerStar Version, rotate the outside lever
3 times to charge the lock, then enter 1,2,3,4,5,6,7,8. You should see a
green light and hear a high pitched tone as you push each button. When the
lock opens, you will briefly hear the sound of an electronic motor. Rotate
outside lever and hold. Ensure that the latch is fully retracted and flush
with the latch faceplate. Release the outside lever; the latch should be
fully extended. When the lock re-locks, you will again hear the mot or.
N-4 If your product is an E24xx, you will have to generate an access code
using the web application to test the lock operation.
N-5 With the door open, verify functionality of the mechanical Key Override as
detailed in Section F.