EasyManuals Logo

KEB COMBIVERT F5 User Manual

KEB COMBIVERT F5
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #109 background imageLoading...
Page #109 background image
109
Max. torque
emergency oper.

The maximum torque during emergency operation is activated through parameter
LF.61. This allows the drive to limit the torque and therefore the output current
to the rated value to prevent the drive from drawing too much current from a
battery back up supply.
Unit: pound feet (lb ft)
Value range: 0.0...torque at the drive’s current limit
Default setting 0.LF.36: For IM: 3 x Rated motor torque
(approx. 3 x LF.17)
For PM: 1.5 x Rated motor torque
(approx. 1.5 x LF.17)
This initial low setting protects the motor from high current in case the
encoder position is wrong. For PM motors to run with 100% load in the
car, it may be necessary to raise this value to 200%...250% of LF.17 based
on the motor manufacturers rated peak torque.
Default setting 1.LF.36 = LF.17
Parameter Description - Control Settings

Table of Contents

Other manuals for KEB COMBIVERT F5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5 and is the answer not in the manual?

KEB COMBIVERT F5 Specifications

General IconGeneral
CategoryDC Drives
Enclosure RatingIP20
Control ModeVector Control, V/f Control
ProtectionOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short circuit
Fieldbus CommunicationPROFIBUS, CANopen
Communication InterfacesRS-485
Input Voltage380-480V AC
Cooling MethodForced air cooling (fan)

Related product manuals