132
7.0 Run Parameters
The run parameters display operational values within the elevator
drive. They can be used for trouble shooting or calibration purposes.
Each parameter is listed below along with a description of what
it displays. Some parameters may display information only
used by factory service personnel during diagnostic or repair.
It is not necessary to understand the function of each of these
parameters.
ru. 0
Inverter state
This parameter displays the operational status of the inverter. The status codes are
de ned with parameter LF.99.
This parameter displays the set speed or commanded value. This value is before
the ramp generator.
Units: rpm
This parameter displays the actual commanded speed of the motor. This is the
speed the motor should turn at.
Units: rpm
This is the actual output frequency to the motor.
Units: Hz
This is the processed actual speed value as measured by the motor encoder.
Units: rpm
This is the raw measured speed value as measured by the encoder connected to
input X3A.
Units: rpm
This is the raw measured speed value as measured by the encoder connected to
input X3B.
Units: rpm
ru. 1
Set speed
ru. 2
Command
speed
ru. 3
Actual output
frequency
ru. 7
Actual speed
value
ru. 9
Encoder 1
speed
ru.10
Encoder 2
speed
Diagnostic Parameters