Parameter Description - Driving Profi le
Intermediate speed one, uses pro le 0 acceleration and decelera-
tion. Can be assigned as emergency operation speed.
Unit: feet per minute
Value range: 0...LF.20
Default setting: 0 ft/min
Adjusted value: dependent on the distance between the
oors
Set Speed S
INT1
,
Intermediate Speed 1
Intermediate speed two, uses pro le 0 acceleration and decelera-
tion. Can be assigned as emergency operation speed.
Unit: feet per minute
Value range: 0...LF.20
Default setting: 0 ft/min
Adjusted value: dependent on the distance between the
oors
Set Speed S
INT2
,
Intermediate Speed 2
Intermediate speed three, uses pro le 0 acceleration and decel-
eration. Can be assigned as emergency operation speed.
Unit: feet per minute
Value range: 0...LF.20
Default setting: 0 ft/min
Adjusted value: dependent on the distance between the
oors
Set Speed S
INT3
,
Intermediate Speed 3

Table of Contents

Other manuals for KEB COMBIVERT F5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5 and is the answer not in the manual?

KEB COMBIVERT F5 Specifications

General IconGeneral
CategoryDC Drives
Enclosure RatingIP20
Control ModeVector Control, V/f Control
ProtectionOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short circuit
Fieldbus CommunicationPROFIBUS, CANopen
Communication InterfacesRS-485
Input Voltage380-480V AC
Cooling MethodForced air cooling (fan)

Related product manuals