Acceleration jerk
Deceleration
Deceleration jerk
Sets the jerk during the roll into constant speed.
Unit: feet per second
3
Value range: (calc. min.
1)
)...32.00 ft/s
3
(oFF)
Default values: Pro le 0 = 4.0 ft/s
3
Pro le 1 = 4.5 ft/s
3
Pro le 2 = 1.5 ft/s
3
Sets the jerk in the roll out of constant speed.
Unit: feet per second
3
Value range: (calc. min.
1)
)...32.00 ft/s
3
(oFF)
Default values: Pro le 0 = 4.5 ft/s
3
Pro le 1 = 5.0 ft/s
3
Pro le 2 = 1.5 ft/s
3
Sets the rate of deceleration.
Unit: feet per second
2
Value range: 0.30...12.0 ft/s
2
Default values: Pro le 0 = 3.5 ft/s
2
Pro le 1 = 3.5 ft/s
2
Pro le 2 = 1.5 ft/s
2
Approach jerk
Set the jerk during the  nal approach to the  oor.
Unit: feet per second
3
Value range: (calc. min.
1)
)...32.00 ft/s
3
(oFF)
Default values: Pro le 0 = 2.5 ft/s
3
Pro le 1 = 3.5 ft/s
3
Pro le 2 = 1.5 ft/s
3
Stop jerk
Sets the jerk and rate of deceleration during the transition from
leveling speed to stop.
Unit: feet per second
3
Value range: off, 0.30...32.00 ft/s
3
Default value: 2.00 ft/s
3
Parameter Description - Driving Profi le

Table of Contents

Other manuals for KEB COMBIVERT F5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5 and is the answer not in the manual?

KEB COMBIVERT F5 Specifications

General IconGeneral
CategoryDC Drives
Enclosure RatingIP20
Control ModeVector Control, V/f Control
ProtectionOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short circuit
Fieldbus CommunicationPROFIBUS, CANopen
Communication InterfacesRS-485
Input Voltage380-480V AC
Cooling MethodForced air cooling (fan)

Related product manuals